Product Introduction
The GT400C vortex flowmeter is a velocity-type flowmeter designed based on the Karman Vortex principle. It is used to precisely measure and control the flow rate of gas, steam, or liquid within industrial pipelines. Applying advanced technology, it can simultaneously measure temperature, pressure, instantaneous flow rate, and totalized flow rate, and supports various communication functions such as RS485 (Modbus RTU), HART, and GPRS.
Product Features
- High Reliability & Maintainability: With no moving parts, mechanical wear is minimized, and the simple structure provides long-term stability and easy maintenance.
- Stable Performance: The output frequency maintains a linear relationship with the flow rate, and there is no zero-point drift, ensuring highly stable performance.
- Energy-Saving Design: Pressure loss is significantly lower, at about 1/4 to 1/2 that of an orifice flowmeter, offering excellent energy efficiency.
- Corrosion Resistance & Durability: Adopting a 316L stainless steel sensor housing, it features strong corrosion resistance against alkaline solutions and most organic/inorganic acids.
- Flexible Installation: Can be installed horizontally, vertically, or tilted at various angles depending on the on-site pipeline conditions.
Applications
- Industrial Fields: Various processes including chemical, environmental protection, pharmaceutical, papermaking, metallurgy, textile, steelmaking, heating, and gas supply.
- Measurable Media: Saturated steam, superheated steam, compressed air, general gases (oxygen, nitrogen, hydrogen, natural gas, etc.), water, and various liquids (gasoline, alcohol, etc.).
General Specifications
| Item | Specifications |
|---|---|
| Implementation Standards | JB/T9249-2015 Industry standards for vortex flowmeters. |
| Nominal Diameter | 15, 20, 25, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300, 350, 400, 450, 500, 600 (DN200 ~ DN3000: Insertion type available) |
| Nominal Pressure | 1.6 ~ 25MPa, ANSI 150LB ~ 2500LB (Other pressure ratings available upon request) |
| Conditions of Use | Medium Temp: Standard type (-45°C~100°C), Medium temp type (-45°C~250°C), High temp type (-45°C~330°C), Ultra-high temp type (-45°C~450°C) Ambient Temp: -20°C ~ 55°C • Relative Humidity: 5% ~ 90% • Atmospheric Pressure: 86 ~ 106kPa |
| Material | Body: SS304 (Other materials available upon negotiation) • Housing: Die-cast Aluminum |
| Vibrational Acceleration | Piezo-resistive: 0.2g |
| Accuracy | ±1%R, ±1.5%R, Insertion type (Plug-in): ±2.5%R |
| Range | 1:20 ~ 1:50 |
| Supply Voltage | Sensor/Transmitter: DC 24V, Battery power supply: 3.6V Battery |
| Output Signal | Pulse output, 4~20mA current output, RS485 (Modbus RTU), HART protocol, IOT GPRS, etc. |
| Pressure-loss Coefficient | JB/T9249 표준 준수 (Cd ≤ 2.4) |
| Explosion-proof Mark | Intrinsic Safety Type: Ex ia II CT6 Gb, Flameproof Type: Ex d II CT6 Gb |
| Protection level | IP65 |
| Electrical Connection | Internal thread M20*1.5, 1/2 NPT, etc. |
| Applicable Medium | Gas, Liquid, Steam |
| Transmission Distance | 2-wire 4-20mA: ≤ 1500m (Load ≤ 500Ω) • RS485 & HART: ≤ 1200m |