Product Introduction
GT400S-A (Sealing Wafer): The wafer type with enhanced sealing performance is a high-precision flow meter utilizing the Karman Vortex principle. With no moving parts, it offers excellent durability and accurately measures various industrial fluids such as gas, steam, and liquids. Equipped with a meticulously designed amplifier board, it provides an optimized solution for long-distance signal transmission and centralized networking management.
Product Features
Enhanced Sealing Performance: A special sealing design is applied to completely block fluid leakage and ensure process safety.
High-Precision Vortex Detection: Using the Karman Vortex principle, it accurately detects minute changes in flow rate without any moving parts.
Vibration Resistance and Durability: Made of robust stainless steel (SUS304/316), it outputs stable data even in environments with vibration.
Intelligent Compensation System: Built-in temperature and pressure sensors automatically compensate for flow errors caused by environmental changes in real-time.
Easy Installation and Compatibility: Due to the wafer type's characteristic light weight and slim size, it can be installed quickly without modifying existing piping lines.
Applications
The GT400S-A model is especially recommended for the following environments where safety and precision are required simultaneously:
High-Pressure Steam Lines: Flow management of superheated steam in boilers and heat exchangers.
Chemical and Refining Processes: Measurement of highly flammable liquids such as gasoline, alcohol, and benzene, which pose high risks in case of leakage.
Gas Supply Systems: Precision metering and loss prevention of industrial gases such as nitrogen, oxygen, and argon.
Food and Pharmaceuticals: Hygienic process lines where cleanliness is crucial and even minute leaks are not permitted.
Energy Management Systems (EMS): Monitoring compressed air consumption in factories and reducing costs.
General Specifications
| Item | Description |
|---|---|
| Material | Cast steel or Stainless steel |
| Accuracy | Flange type: ±1.0% within 4.5 to 55 m/s range, 2.0% outside that range / Insertion type: 2.0 to 2.5% |
| Medium | Gas, Steam, Liquid |
| Diameter | Full-bore type: DN15 to DN300,Insertion type: DN150 to DN2000 |
| Output | Standard: 4-20mA / Pulse,Option: RS485 Communication |
| Max. Press. | Wafer/Insertion type: 1.6 MPa,Flange type: 1.6 / 2.5 / 4.0 MPa |
| Power | DC24V (Max. 100mA, 2W) and 3.6V Lithium Battery |
| Protection | IP65 |
| Temperature | Standard: -20°C to 350°C, -20°C to 250°C |
| Compensation | Built-in high-temperature/high-pressure sensors support automatic temperature and pressure compensation |