■ Mobile App UI Screen

■ System Configuration

■ Product Introduction

GFMR-78T 폐수 처리용 블랙 나일론 하우징후랜지 타입 시리즈는 자외선 노출이 심한 야외 개방형 현장과 가벼운 가스가 발생하는 하폐수 처리장에 특화된 특수 구조형 레이더 레벨 미터입니다. 고가 사양인 PTFE(테플론) 안테나가 탑재되어 습기와 미세 부식성 대기 속에서도 안정적인 성능을 유지하는  최적화된  78GHz 고주파 FMCW(주파수 변조 연속파) 레이더 레벨 미터입니다. 빔 각도가 좁아 정밀한 조준이 가능하며, 상하수도, 저수지, 강하천 등 물 관련 모든 현장에서 기후 변화에 영향을 받지 않고 가장 안정적이고 정확한 수위 데이터를 제공하는  레이더 레벨 미터(수위계)입니다.

■ Applications

  • Water Resources & River Management: Outdoor open-channel level measurement for wastewater treatment plant sedimentation tanks, rivers, streams, reservoirs, and dams.

  • Industrial Water Tanks: Water tanks with lingering mild chemical gases, outdoor open channels, and outdoor water tanks.
  • Environmental Monitoring: Real-time water level monitoring systems for torrential rain and flood prevention.

  • Environmental Monitoring: Real-time water level monitoring systems for torrential rain and flood prevention.

■ Key Features

  • Water Measurement Optimization & High-Precision Metering: Delivers highly precise and consistent measurement performance through an integrated algorithm that compensates for minute surface ripples or distortions.
  • Powerful Linearity of 78GHz FMCW: Featuring an exceptionally narrow beam angle of approximately 6.8°, it accurately targets only the water surface without wall interference (false echoes), even inside manholes with numerous structures or narrow channels.
  • Available in distinct measurement ranges of 10m, 20m, and 30m depending on the model.
  • Optimized measurement coverage in low-clearance spaces with a minimal dead band of less than 150 to 180mm.
  •  Supports simultaneous output of 4-20mA analog signal and RS485 Modbus communication.
  • Configurable via Bluetooth using a dedicated mobile app, allowing operators to verify measurement values in real-time.
  • Weather-Resistant Black Nylon Structure: A dual-layer rigid structure that prevents housing deformation or cracking, even during long-term exposure to direct sunlight (UV) and harsh weather conditions.
  • Environmental Resilience: Utilizes a non-contact measurement method to prevent sensor contamination, ensuring stable operation without signal attenuation under severe outdoor conditions such as heavy fog, steam, rain, wind, and temperature fluctuations.
  • Offers a cost-effective and seamless replacement for conventional ultrasonic level meters and 26GHz radar level meters, effectively overcoming their technological limitations.

■ Precautions

  • Outdoor Protection Measures: When installing in open outdoor locations exposed to year-round direct sunlight or lightning risks, it is highly recommended to equip a sunshade (UV protection cover) and a surge protector.
  • Measurement Restrictions: Measurement may be restricted in highly corrosive chemical environments (such as strong acids and alkalis) or high-temperature, high-dust processes; please apply to standard water supply and wastewater treatment applications.
  • Maintaining Minimum Distance (Dead Band): Properly adjust the installation height so that the maximum water level does not breach the dead band zone directly in front of the sensor (approximately 0.08m to 0.1m depending on the model).
  • Surface Alignment Angle: The antenna radiation surface must be precisely aligned perpendicular ((90°) to the water surface to collect optimal reflected wave signals. If the antenna becomes contaminated, gently wipe it with a soft cloth.

  • Rainwater Ingress Prevention: Tighten the waterproof cable gland securely and bend the cable downward into a "U" shape (drip loop) to prevent rainwater from running along the cable and entering the housing interior.
  • Radio Regulatory Compliance: Prior agreement with the relevant radio observatory is required if the installation is intended within a 2 km radius of a radio astronomy antenna.

■ General Specifications

● Model GFMR-78T
● Frequency 77~81GHz
● Max. Measurement Distance Max. 30m
● Application Liquid
● Accuracy ±2~3mm
● Repeatability ≤1–2mm
● Beam Angle 6.8°
● Dead Band 180~200mm
● Power Supply DC 24V/ 2 wire system for 4-20mA DC
DC 24V/ 4 wire system for 4-20mA DC
● Signal Output 4-20mA DC/ Loop wire + RS485 Modbus
● Calibration Debugging via Bluetooth and RS485 Modbus
● Display -D: LCD Display
-N: No
● Language LCD Display: English
Bluetooth: Korean
● Process Temperature -40~60℃
● Process Pressure Max. 2 Kpa
● Ambient Temperature Output: -40°C to 55°C
● IP Rating IP67
● Antenna Type & Material Lens Type / Standard PP Antenna (Option: PTFE)
● Housing Material -D: ABS (Color: Orange, Blue, Black)
-N: SUS304, Aluminum Anodizing (Black), ABS (Orange, Black)
● Process Connection -D: Thread G1.5”
-N: Thread G1.5", G2", Thread M76x2 (For Dual Hard Structures)
● Cable Entry -D: M12*1.5
-N: M16x1.5+Cable: 0.45mm² x 1m, PT 1” adapter
● Adjustment 4 Buttons, Bluetooth, RS485 Modbus
● Options -D: Split Flange
-N: Split Flange or Bracket
    Flange Hard Structure (Material: Black Nylon)
Remarks: -D: Display Type / -N: Non-display Type

■ Product Selection Code

Model Code Description
Model: GFMR-78T_FMCW Radar Level/ Distance Meter
Indicator D ABS Housing, LCD display +4 buttons
Blue-tooth and RS485 debugging
Cable gland: M12x1.5 & Blind
Process Connection: Thread G1.5”
N SUS, Al Anodizing Housing, No display with signal cable-1m
Blue-tooth and RS485 debugging
Process Connection: Thread G1.5”, G2” (Option: PT 1”)
Measurement Range 10 Max. 10m
20 Max. 20m
30 Max. 30m
Option Y Yes
N No
Option: Please fill in required items only.
Process Connection
/ Material
B Bracket/ SUS304 (SUS, Al housing only)
P-1 PP Thread G1.5” (For Al, SUS housing)
P-2 PP Thread G2” (For Al, SUS housing)
S-2 SUS Thread G2” (SUS housing only)
F( )( ) Flange:
(5) DN50, (8) DN80, (10) DN100
(O) Other
(J) JIS 10K
(D) DIN PN16
(A) ANSI 150#
( ) Flange 재질: (A) Al, (S) SUS304, (P) PVC, (T) PTFE
4 Option Output: 4 wire system for 4-20mA.
T Special antenna: 재질: PTFE
-D Double construction: ABS body, Thread M76x2 only
(JIS, DIN, ANSI: More than 50A Flange) (Material: Black Nylon)
For remote indicators, please refer to the attached catalog if necessary and place a separate order.
Required Specifications for Product Ordering
  • 1) Base Product Model
  • 2) Measurement Range and Maximum Upper Level
  • 3) Type of Fluid, Process Temperature, and Process Pressure
  • 4) Measurement Range, Tank Shape, Connection Nozzle and Dimensions: W, D, H
  • 5) Type and Material of Connection Flange (Default: Black Nylon, Aluminum, Stainless Steel, etc.)
  • 6) Additional Options and Precautions